Welcome to Biz Trade Circle, We have highest range of cosmetics

Revolutionize Your B2B Trade Experience with Biz Trade Circle

VivaChek Dual Meter Replacement Strips: Full Specifications

VivaChek Dual Test Strips measure blood glucose and beta-ketone from one sample and work with VivaChek Dual and Dual BLE meters.

Overview: What the VivaChek Blood Glucose and β-Ketone Dual System Offers

For individuals who need to track both blood glucose and β-ketone levels, sourcing replacement strips and understanding the full specifications of a compatible meter matters as much as the device itself. The VivaChek Blood Glucose and β-Ketone Dual System, developed by Weice Biotech under the VivaChek brand, addresses a recurring industry pain point: blood glucose and ketone monitoring often requires separate test strips, separate meters, manual coding, larger blood samples, and limited data connectivity. VivaChek’s strategic positioning centers on a one-meter, one-strip dual testing system for blood glucose and β-ketone, with auto coding and an optional Bluetooth data management option, so users are not forced to manage two separate testing workflows.

Core Technology Behind the Dual-Measurement Strip

The system relies on an electrochemical biosensor platform. Glucose is measured using glucose dehydrogenase, while β-ketone is measured using β-hydroxybutyrate dehydrogenase. Both reactions occur on a single test strip, which is the foundation of VivaChek’s differentiated value: one test strip simultaneously measures blood glucose and β-ketone, removing the need for separate strips or meters. This single-strip approach is paired with auto coding, which automatically identifies and reads the coding information of each test strip, lowering the risk of coding error that can occur with manual coding systems.

Replacement Strip and Meter Specifications

For anyone evaluating replacement strips or the meter they pair with, the key technical metrics are:

  • Glucose measurement range: 20–600 mg/dL
  • β-ketone measurement range: 0.1–8.0 mmol/L
  • Result calibration: Plasma-equivalent
  • Coding method: Auto-Coding
  • Sample type: Fresh capillary whole blood from the fingertip
  • Sample size: About 1.6 microliters
  • Testing time: About 12 seconds
  • Hematocrit range: 20–65%
  • Measurement units: Glucose in mg/dL; ketone in mmol/L
  • Sample application: Wicking action, end-fill
  • Operating temperature: 45.5°F–113°F (7.5°C–45°C)
  • Operating humidity: 10–90% R.H. non-condensing
  • Test strip storage temperature: 36°F–86°F (2°C–30°C)
  • Test strip unopened shelf life: 24 months
  • Test strip opened shelf life: 6 months

These figures show that the strips are designed for a wide hematocrit range of 20–65%, which reduces bias across more users and more testing conditions than a narrower range would allow. The short 12-second test time and small 1.6-microliter sample size are also central to the product’s convenience positioning, since smaller samples and faster results typically mean fewer barriers to routine self-monitoring.

Meter Hardware and Bluetooth Connectivity

Beyond the strip chemistry, the meter itself carries its own specification set relevant to anyone asking about the "BLE meter" variant:

  • Battery: Rechargeable 250 mAh, 3.7 Volt DC nominal, lithium polymer battery, with 5V input charge voltage
  • Charging port: USB Type-C
  • Automatic shutoff: 120 seconds after the last action
  • Beep function: Yes
  • Backlight: Yes
  • Bluetooth: Optional, version 5.1
  • Hypo warning: Yes
  • Test averaging: No
  • Strip ejector: No
  • Ketone warning: No
  • Meal markers: No
  • Test alarms: No
  • Memory: 300 records with date and time

The optional Bluetooth Low Energy version 5.1 connection links the meter to the VivaChek GlucoKet App, allowing data generated from the 300-record memory to be transferred for ongoing review. The USB Type-C charging port reflects a modern approach to power management, replacing older charging formats still common in some point-of-care devices.

Analytical Performance Behind the Numbers

Specifications are only meaningful if the underlying measurement performance holds up. According to the provided analytical data, meter results clustered along the fitted regression line with strong linearity, an R² greater than 0.96, a slope of approximately 1, and no obvious bias. Specifically, glucose results showed good agreement with the comparator method, with R² = 0.97 and a slope of approximately 1. β-ketone results showed an even tighter linear fit, with R² = 0.996, a slope of approximately 1, and an intercept of approximately 0. These statistics indicate that both analytes track closely with reference methods across the stated measurement ranges.

Interpreting Results: Reference Guidance

The product documentation includes interpretation references drawn from recognized clinical sources. For fasting glucose: normal is below 100 mg/dL, prediabetes is 100–125 mg/dL, high is at or above 126 mg/dL, and low is below 70 mg/dL. For β-ketone: normal is below 0.6 mmol/L, mild elevation is 0.6–1.5 mmol/L, moderate ketosis is 1.5–3.0 mmol/L, and severe ketosis is above 3.0 mmol/L. These reference ranges are drawn from the American Diabetes Association’s Standards of Care in Diabetes—2023 and the International Society for Pediatric and Adolescent Diabetes’ Clinical Practice Consensus Guidelines on Diabetic Ketoacidosis and Hyperglycemic Hyperosmolar State, giving users a documented basis for interpreting their dual results rather than relying on glucose-only or ketone-only norms.

Why the Dual-Strip, Dual-Meter Design Matters in Practice

Separate glucose and ketone testing routines typically increase the number of supplies, steps, and overall cost involved in metabolic self-monitoring. Manual coding on many devices can also introduce result errors if a user enters the wrong code. VivaChek’s design responds to both issues directly: fewer consumables because one strip measures glucose and β-ketone, and easier operation because auto coding removes a manual step that is prone to mistakes. The roughly 12-second result supports timely metabolic decisions, while the wide hematocrit range helps maintain accuracy across a broader range of users than a narrower hematocrit specification would allow.

Delivery and Deployment

The VivaChek Blood Glucose and β-Ketone Dual System is delivered as a hardware meter paired with disposable test strips, with an optional Bluetooth Low Energy companion app connection for users who want to log and review their glucose and ketone history over time. This structure keeps the core testing hardware simple while giving users the choice to add connected data management when it fits their monitoring needs.

For anyone comparing replacement strip specifications or meter capabilities, the combination of a 20–600 mg/dL glucose range, a 0.1–8.0 mmol/L β-ketone range, a 1.6-microliter sample, a 20–65% hematocrit tolerance, and optional Bluetooth 5.1 connectivity defines what the VivaChek Blood Glucose and β-Ketone Dual System, from Weice Biotech, brings to point-of-care metabolic monitoring.

Reviews

There are no reviews yet.

Be the first to review “VivaChek Dual Meter Replacement Strips: Full Specifications”

Your email address will not be published. Required fields are marked *

Category:
Select Language